The PNS series magnet control units (voltage transducers) are designed to control any types of lifting magnets or groups of magnets totaling the maximum operational amperage at 125A (PNS-300) and 200A (PNS-600) at Tmc = 20 °C)*.
* * Tmc - temperature of the magnet's coil.
The following are the basic advantages of the PNS series control units as compared to the currently in-use PMS-15 series and the like:
PNS-300-20-121 | PNS-300-30-141 | |
Output voltage, DC, V | 230+5% | 230+5% |
ДVoltage adjustment range, V | 10-230 | 10-230 |
Maximum operational amperage, A (Tmc = 20 ºC) | 125 | 200 |
Productive time operational mode % | 75 | 75 |
Degaussing time, sec, not exceeding | 3 | 3 |
Power supply | Three-phase AC supply-line without work neutral terminal
380 +10% /-15% V, 50 Hz |
Three-phase AC supply-line without work neutral terminal
380 +10% /-15% V, 50 Hz |
Operational cycle, not exceeding, min | 10 | 10 |
Dimensions, not exceeding, mm | 320х320х120 | 410х360х165 |
Mass, not exceeding, kg | 7 | 12 |